Certified Cardiac Medical Device Distributor

CALL 888-891-1200 Email an Order

REQUEST PRODUCT INFO

  • MED Alliance Group
  • An Experienced Medical Device Distributor

  • REQUEST PRODUCT INFO

  • Panther 5N Ventilator: NIV As It Should Be

    1. Home
    2. /
    3. Uncategorized
    4. /
    5. Panther 5N Ventilator: NIV As It Should Be

    Panther 5N Ventilator: NIV As It Should Be

    Origin Medical Devices Panther 5N NIV Ventilator with Smart Trigger Technology
    Panther 5N from Origin Medical Devices NIV as it should be

    Innovative, Intelligent SMART Trigger Provides Optimal Synchrony

    Improve Trigger Detection, Reduce Trigger Delays

    Severe or variable leaks are a common factor in NIV failure. Synchrony is critical for successful weaning, reducing time on the ventilator as well as NIV success. SMART Trigger is the key synchrony tool for detecting patient triggers even under the most difficult conditions.

    The Panther line of ventilators from Origin Medical Devices features the SMART Trigger, a proprietary algorithm that improves synchrony and reduces the patient’s work of breathing in both noninvasive and invasive applications. The SMART Trigger has a novel approach to reduce trigger delays and reliably detect weak ineffective patient efforts where conventional triggers fail.

    Panther 5N NIV Ventilator Features SMART Trigger

    The Origin Medical Devices Panther 5N Ventilator is a high-acuity level, dedicated non-invasive ventilator that features SMART Trigger technology and supports any patient from neonates to adults. The P5N Ventilator’s powerful, high-performance dual-stage blower supports patients, even in the toughest respiratory scenarios. With Origin Medical’s patented proportional flow valve and state-of-the-art algorithms, the Panther 5N provides unmatched leak compensation, regardless of the mask type used.

    Panther 5N Highlights

    • Maintains perfect synchrony in the presence of high leaks
    • Immediate delivery of very high flows on patient demand
    • HFO2 and emergency invasive ventilation capabilities
    • Use with a variety of circuits and masks, including vented masks
    • Independent from compressed air
    • No expensive maintenance needed
    • Intuitive, easy-to-use interface
    • Neonates to adults
    • Optimal solution to replace the Phillips V60

    Panther 5N Specifications and Capabilities

    • Screen size: 15″
    • High-performance touch screen for ease of control
    • NIV modes: PCV, S/T, AVAPS / SPONT / CPAP
    • NIV terminology and modes: IPAP/EPAP
    • Invasive modes: PC, S/T, AVAPS
    • Oximetry
    • Capnography
    • Integrated Nebulizer (Pneumatic and Aerogen)
    • 240 LPM of flow and 200 LPM of leak compensation, delivering immediate trigger response
    • Pressure delivery range: 100 cmH20
    • Volume range: 20ml – 2500ml (Neo 5ml – 2500ml)
    • Adjustable PEEP max: 50 cmH2O

    For a demo, evaluation or more information about the Origin Medical Devices Panther Ventilators from Solutions in Critical Care, contact your local MED Alliance Group sales representative, call 888-891-1200 or email us.

    MED Alliance Group is a medical device distributor that has been meeting the needs of our clinical customers and manufacturing partners since 1998. We specialize in the sales, marketing, importation, logistics and distribution of innovative, high-quality and cost-effective products found in anesthesia and respiratory, blood and transfusion therapy, EMS and emergency room, interventional radiology and cath lab, iv and vascular, as well as NICU and PICU.

    Please follow us on LinkedIn, Facebook and Twitter for MED Alliance product updates.

  • Contact Information

  • MED Alliance Group, Inc.
    2175 Oakland Drive
    Sycamore, IL 60178

  • TOLL FREE: 888-891-1200
    PHONE: 630-443-7070

  • Copyright © 2023 MED Alliance Group, Inc. REP LOGIN PROUD MEMBER OF IMDA

  • X